EG8208

8 Serial Ports Edge Gateway

  • Interface type:  8RS485/8DO/1LAN
  • Protocol support:  Modbus/PLC/RTU/TCP/MQTT/HJ212/PLC……
  • Network type:  4G
  • Features:  8 serial edge computing data bi-directional transmission of multiple modes of operation Modbus RTU/TCP transfer and customized JSON format reporting

 

Categories: ,

Description

EG8208 is a professional 8-channel independent isolated RS485 communication controller. With Modbus and JSON support, flexible TCP/IP and UDP switching, built-in monitoring and self-diagnostic features. Widely used in industrial automation, building management and other fields. Provide users with excellent data acquisition and device management solutions.

EG8208 detail page - -EN_01EG8208 detail page - -EN_02EG8208 detail page - -EN_03EG8208 detail page - -EN_04EG8208 detail page - -EN_05EG8208 detail page - -EN_06EG8208 detail page - -EN_7EG8208 detail page - -EN_8EG8208 detail page - -EN_9EG8208 detail page - -EN_10EG8208 detail page - -EN_12EG8208 detail page - -EN_13EG8208 detail page - -EN_14EG8208 detail page - -EN_15EG8208 detail page - -EN_16EG8208 detail page - -EN_17EG8208 detail page - -EN_18EG8208 detail page - -EN_19EG8208 detail page - -EN_20EG8208 detail page - -EN_21EG8208 detail page - -EN_22

EG8000 Series Edge Computing Gateway PLC Protocols

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents. Note: The gateway supports the standard MOBUDS RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

BrandProtocolInterfacePLC Model
SIEMENSTips:Siemens in the sale of the series all support S7 protocol communication, it is recommended to use the S7 protocol communication.
S7EthernetS7-S200smart, S7-S200 Series, S7-S300 Series, S7-S400 Series, S7-S1200 Series, S7-S1500 Series
PPISerial portS7-200 Series
MELSECTips:Mitsubishi mainly uses MC protocol for communication, FX5 Series, FX3 Series, Q Series, etc. are tested.
EtherNet/IPEthernetFX5-ENET/IP Series, RJ71EIP91 Series, QJ71EIP71 Series
MC-1E/MC-3EEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series, QnUCPU Series, FX3 Series
MODBUS TCPEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series
MC-3CSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series
MODBUS RTUSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series, FX3 Series
FxLinksSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
FxSerialSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
OMRONTips:Omron mainly uses the Fins protocol for communication.
EtherNet/IPEthernetNX7 Series, NX1 Series, NX1P Series, NJ Series, CJ1W-EIP21
FinsEthernetCP Series, CS Series, CJ Series, CV Series
HostLinkSerial portCP Series, CS Series, CJ Series, CV Series, C Series
LSisTips:LS mainly uses FEnet/Cnet protocol for communication.
XGB FEnetEthernetXGB Series (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT Series (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerial portXGB Series (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerial portXGT Series (XGL-CH2A, XGL-C21A, XGL-C41A)

BrandProtocolInterfacePLC Model
AllenBrandlyTips:Rockwell mainly uses CIP, DF1 protocol for communication.
EtherNet/IPEthernetControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870)
DF1Serial portControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500)
BeckhoffTips:Beckhoff mainly uses the ADS protocol for communication.
ADSEthernetCX Series, TwinCAT2, TwinCAT3
InovanceTips:Inovance mainly adopts MODBUS protocol for communication.
MODBUS TCPEthernetAC Series, AM Series, H5U Series, H3U Series
MODBUS RTUSerial portAC Series, AM Series, H5U Series, H3U Series, H1U Series
KeyenceTips:Keyence mainly uses the KV protocol for communication.
MC-3EEthernetKV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units
KVEthernet
KVSerial portKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTips:Panasonic mainly uses the Mewtocol protocol for communication.
MC-3EEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolSerial portFP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series
DeltaTips:Delta mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetAH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet)
MODBUS RTUSerial portAH Series, AS Series, AX-3 Series, DVP Series
XinJETips:XinJE mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetCCSD Series, XA Series, XS Series, XG Series, XL Series
MODBUS RTUSerial portCCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series
MegMeetTips:MegMeet mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
MODBUS RTUSerial portMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
YaskawaTips:Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) .
MemobusEthernetGL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series
FatekTips:Fatek mainly uses the Fatek protocol for communication.
FatekSerial portFBs Series
VigorTips:Vigor mainly uses the VS private protocol for communication.
VSSerial portVS Series
FujiTips:Fuji mainly uses the SPH/SPB protocol for communications.
SPHEthernetSPH Series
SPBSerial portSPB Series

HardwareCPU2*Cortex-A7@1.2GHz
Memory512M
EMMC4G(MLC)
SD cardUp to 128G (influxdb pre-installed)
RTCReal Time Clock
WirelessLTE Cat4
WAN1*1000/M Support DHCP Client
LAN1*100/M Support DHCP Server
WiFiAP+Station
GPSSupport GPS satellite location
USB1*USB 2.0
RS4852*Isolated RS485
RS2321*Isolated RS232
CAN2*Isolated CAN
DO2*Isolated relay Output (10A/250VAC 30VDC)
DI2* Isolated relay Input (Wet&Dry nodes)
LEDSupport DO/DI status indication (customizable)
Electrical
Parameters
Rated VoltageDC12V, DC9~36V(Working Range)
Rated Power<5W
Power ProtectionAnti-static, anti-surge, anti-reverse
CertificationCE/ROHS/FCC
Environmental
Parameters
Operating Temperature-40~85℃
Storage Temperature-40~85℃
Environment Humidity10-90%RH (non-condensing)
Cooling MethodHeat sink/Dissipation silicone
Mechanical
Parameters
Size157*112.8*28.8mm
Weight<1kg
MaterialZinc Alloy
Software
Parameters
OpsSupport remote configuration/upgrade/management
VPNSupport intranet penetration/PLC remote upload&download/virtual serial port
Edge ComputingSupport visual programming, zero-code development, drag-and-drop programming, secondary development, compilation-free
Data StorageSupport cache queues/file read&write/disconnected transfer/ influxdb
Industrial AgreementSupport multiple industrial protocols
Support hundreds of PLCs (see appendix for details)
Network ProtocolMQTT/HTTP/TCP/UDP

Contact us

X

Contact us

Contact us