ET1020 – Analog IO Module
ET1020 is an analog IO expansion module, including 4 channels of 4-20mA analog input and output. The module supports MODBUS RTU protocol, supports cascading, non-inductively expands the number of IO interfaces, and does not require configuration, plug and play, adaptive master-slave station, adaptive register address, has communication delay of milliseconds, and high-speed communication without packet loss or abnormality. , hardware indicators present communication status in real time and other features. It can be used with the main device ET3410 for better results.
More details…
Description
- Support MODBUS RTU protocol
- Support cascading, non-inductive expansion of I/O ports
- No configuration required, Plug and play
- Adaptive master-slave, adaptive register address
- Communication delay in milliseconds
- High-speed communication without packet loss and abnormality
- The hardware indicator light presents the communication status in real time
RS485 | Number of ports | 1 way |
Operating mode | Slave |
Support baud rate | 115200/9600/4800/2400 |
AO | Number of ports | 4 way |
Output type | 4-20mAoutput |
Sampling accuracy | 12bit |
AI | Number of ports | 4 way |
Input type | 4-20mAenter |
Sampling Accuracy | 12bit |
Electrical Parameters | Rated voltage | DC12V, working range DC12~24V |
Rated power | <1W |
Power protection | Anti-static, anti-surge, anti-reverse connection |
Environmental Parameters | Operating temperature | -40~80℃ |
Storage temperature | -40~85℃ |
Environment humidity | 10-90% RH (non-condensing) |
Mechanical Parameters | Size | 80*71*63mm |
Weight | 150g |
Material | ABS |
Serial number | Name | Meaning | Serial number | Name | Meaning |
---|
1 | Pow | Power indicator light, always on | 18 | GND | AI signal input ground |
2 | work | Working indicator light, 1 second strobe | 19 | AI4 | AI4signal input |
3 | Net | reserve | 20 | GND | AI signal input ground |
4 | Recv | reserve | 21 | RST | reset button |
5 | send | reserve | 22 | AO1 | AO1signal output |
6 | -- | reserve | 23 | GND | AO Signal output |
7 | alarm | Alarm indicator light, always on after cascaded device communication abnormal | 24 | AO2 | AO2 signal output |
8 | link | Connection indicator, always on after cascaded device plugged in | 25 | GND | AO Signal output |
9 | Vin | Power input positive stage | 26 | AO3 | AO 3signal output |
10 | GND | Power input negative | 27 | GND | AO Signal output |
11 | 485A | RS485-A | 28 | AO4 | AO 4signal output |
12 | 485B | RS485-B | 29 | GND | AO Signal output |
13 | AI1 | AI1 signal input | 30 | Dial code | 1-5 means the MODBUS communication address, restart to take effect |
14 | GND | AI signal input ground | 31 | Dial code | 6-8 Set the baud rate, restart to take effect |
15 | AI2 | AI2 signal input | 32 | M | M port, for upward cascading |
16 | GND | AI signal input ground | 33 | S | S port, for cascading down |
17 | AI3 | AI3 signal input | | | |